Chapter 8: Installation 8-13
Display Unit
Connection
Display Unit Connection
Therearof the display providesthe followingconnection sockets:
Scanner(antenna)connection
hsb
2
,in/outconnectorforconnectingtoanotherhsb
2
orHSBseriesdisplay.
SeaTalk,forSeaTalkdatainputandoutputandconnectingtoanother
hsb
2
seriesdisplay(suchasachartplotter or second radardisplay).
NMEAOutput,forNMEAdata outputinanintegrated system.
Power/NMEAInput,for 12 V, 24V or32 VDCpower connection,two
NMEA0183inputsand one RF ground(screen)connection.
Figure 8-6: Radar Display Connector Panel
Thefollowingsectionsdetailthedisplayunitconnectorsusedwheninstalling
asingle
hsb
2
seriesdisplay.The remainingconnectordetailsare providedin
Section 8.8.
NMEA
OUT
POWER/NMEA
TRANSDUCER
SeaTalk
HSB
R
G
Y
To NMEA instruments
NMEA IN 2
D5576-1
POWER IN
NMEA IN 1
To other hsb
2
displays
To SeaTalk
instruments/GPS
To radar scanner unit