Chapter 2: SmartPilot Commissioning 23
Step 4 - Adjust key SmartPilot settings
The next step in the commissioning process requires the adjustment of some
key settings. To achieve this you will need to enter one of the four calibration
modes, Dealer Calibration. For more information on the various calibration
modes and their uses see page 39.
Enter Dealer Calibration mode
As improper use of the Dealer Calibration settings can seriously impair
SmartPilot performance, we have made entry to the Dealer Calibration mode
more difficult. Ensure you follow the instructions in this step carefully.
1. Start with the SmartPilot in STANDBY mode.
2. Enter DEALER CAL as follows:
Note: For more information on SmartPilot settings, refer to Chapter 3:Ad-
justing SmartPilot Settings
ST6001 Controllers ST7001 and ST8001 Controllers
press and hold the standby key for two
seconds to enter the Calibration mode
when the screen shows DISPLAY CAL,
press the disp key until you see the
DEALER CAL screen
•press the auto key: the display will
change to CAL ?
•press -1 and +1 together to enter Dealer
Calibration mode
press and hold the standby key for two
seconds to enter the Calibration mode
when the screen shows DISPLAY CAL,
press the disp, up or down arrow
key until you see the DEALER CAL screen
press the auto key: the display will
change to CAL ?
•press -1 and +1 together (ST7001) or
press up and down arrow keys
together (ST8001)
to enter Dealer Calibration mode
At the CAL ? screen, press + together to enter DEALER CAL
2 sec
x3
C
A
L ?
-1 +1
or
D6322-1